Laparosc Endosc Surg Sci . 2004; 11(3): 121-124
Intrathoracic knotting of guide-wire: videothoracoscopic treatment
A. Kürşat Bozkurt1, Lale Yüceyar2, Ahmet Demirkaya1, Tülay Samancı3, Gökçe Şirin1, Mete Burak Özdemir11İstanbul Üniversitesi Cerrahpaşa Tıp Fakültesi Göğüs Kalp ve Damar Cerrahisi Anabilim Dalı, İstanbul
2İstanbul Üniversitesi Cerrahpaşa Tıp Fakültesi Anestezioloji Anabilim Dalı, İstanbul
3İstanbul Üniversitesi Cerrahpaşa Tıp Fakültesi İç Hastalıkları Anabilim Dalı, İstanbul
We present a case of an intrathoracic guide-wire extravasation and knotting in a 75 year old woman following catheter insertion for hemodialiysis. Intrathorasic extravasation caused right apical hemotoma and total pneumothorax. The guide-wire was removed with thoracoscopic approach.
Keywords: Catheter, extravasation, videothoracoscopy
İntratorasik J teli düğümlenmesi: Videotorakoskopik tedavi
A. Kürşat Bozkurt1, Lale Yüceyar2, Ahmet Demirkaya1, Tülay Samancı3, Gökçe Şirin1, Mete Burak Özdemir11İstanbul Üniversitesi Cerrahpaşa Tıp Fakültesi Göğüs Kalp ve Damar Cerrahisi Anabilim Dalı, İstanbul
2İstanbul Üniversitesi Cerrahpaşa Tıp Fakültesi Anestezioloji Anabilim Dalı, İstanbul
3İstanbul Üniversitesi Cerrahpaşa Tıp Fakültesi İç Hastalıkları Anabilim Dalı, İstanbul
Bu yazıda 75 yaşındaki bayan olguda hemodializ amaçlı katater takılması sırasında gelişen intratorasik J teli ekstravazasyonu ve düğümlenmesi bildirilmiştir. İntratorasik ekstravazasyon sağ apikal hematom ve total pnömotoraksa yol açmıştır. J teli videotorakoskopik olarak çıkartılmıştır.
Anahtar Kelimeler: Katater, ekstravazasyon, videotorakoskopi
Corresponding Author: A. Kürşat Bozkurt
Manuscript Language: English